SC Membrane Tape - Rainwater Attenuation Systems
Application
The SC Tape is used in conjunction with SC Membrane in providing an impermeable lining system for attenuation tanks. Taped joints are suitable for the majority of attenuation tank systems. However, in areas of high water table or contaminated ground welded or prefabricated joints, higher specification membranes and protection geotextiles should be considered. For more information on these solutions please fill out an enquiry form or contact the Burdens Environmental sales team.
Performance
Made of inert materials, does not set or cure after placement in the joint
Movement accommodation; /-15%
Tensile strength: 98 Kpa
Shear strength: 46 Kpa
Approved for use with potable water WRC Approval No. 9705502
Outdoor service temperature: -40oC to 90oC
Surface Preparation
All surfaces should be clean, dry and free from frost, grease and loose material.
Application temperature range: 5oC to 30oC.
Application details
Apply directly from the reel onto one surface pressing to give adequate initial adhesion. Remove backing paper and apply other surface onto strip pushing firmly to ensure good contact with full area of strip along the length of the joint.
Health & Safety
There are no known health hazards associated with the product in normal use.
Wash hands immediately after use.